Instructions for Use: Versions, Scope and What to Check
Quick Answer — An IFU is a controlled document, and its value depends on three fields: version, effective date, and the market it was written for. A copy without those is not usable in a registration dossier and is unsafe in practice, because procedure and performance claims change between revisions.
What an IFU must state
| Section | Why it matters |
|---|---|
| Intended use | Defines the claim; the basis of any regulatory or tender statement |
| Specimen type and handling | Where most field errors originate |
| Procedure | Including timing and temperature conditions |
| Performance | LoD/LoQ, precision, and any clinical performance stated |
| Limitations | Interference, hook effect, cross-reactivity |
| Storage and stability | Kit and sample |
| Version and effective date | Determines whether the document is current |
Data pending. This section reports measured values from internal validation studies. They are published once the supporting study is complete; the current report is available from technical support on request.
Requesting a copy
Include the product name, catalogue number, reagent lot if the question is batch-specific, and the intended use of the document — a registration submission and a bench reference may need different formats and languages.
Data pending. This section reports measured values from internal validation studies. They are published once the supporting study is complete; the current report is available from technical support on request.
Checking that the document matches your lot
- Compare versions. An IFU older than the reagent lot should be replaced before use.
- Check the specimen type. A method transferred to a new matrix without a revised IFU is out of scope.
- Check the performance figures. If the IFU states a different LoD or precision from the page you relied on, the IFU governs the product and the difference should be reported.
- Check the language. For registration, the market language is usually mandatory.
Common discrepancies and what they mean
| Observation | Likely cause | Action |
|---|---|---|
| IFU older than the lot | Document not updated with the lot | Request current version |
| Performance figure differs from site | Site summarises across products | Confirm which applies; report |
| Specimen type differs from practice | Local adaptation without revision | Stop; confirm scope |
| Language mismatch | Market-specific versions | Request the correct market version |
Six traps
- Using an IFU without a version check. The most common documentation error.
- Treating the website as the controlled document. It is a summary.
- Adapting procedure locally without a revised IFU. Moves the assay out of its validated scope.
- Assuming one IFU covers all markets. Registration status differs.
- Ignoring the limitations section. It is where the failure modes are documented.
- Filing a superseded version in a dossier. Invites a question that delays review.
The Author’s Take
Position. Publishing IFUs online, with version history, is the single most credibility-building act available to a diagnostic manufacturer — and it is usually avoided for reasons that do not survive inspection.
Reasoning. The worry is that a public IFU invites comparison and criticism. But the realistic alternative is worse: buyers receive a document by email, cannot verify its currency, and either delay a submission or use a superseded version. Both outcomes cost the vendor more than any criticism. A public library with versions and dates also demonstrates a functioning document control system, which is exactly what a distributor’s quality audit is looking for — and it converts a support task into a competitive signal.
Disclosure. Structural page pending document publication. markers indicate where the current IFU structure and request route must be inserted.
Related pages
Sources
- Reference to be added.
- Reference to be added.
Frequently asked questions
- How do I know I have the current IFU?
- Every IFU carries a version identifier and an effective date. Compare the revision date with the reagent lot in use: if the IFU predates the lot, request the current version before running patient samples.
- Does an IFU cover every market?
- Not necessarily. Intended use, registration status and language requirements vary by market. Confirm that the document you hold corresponds to the market where the product is registered, not only to the product.
- What should I do if the IFU performance data differs from the website?
- Treat the difference as information. The IFU is the controlled document for the product; the website summarises across products and may lag a revision. Report the discrepancy so the correct document can be confirmed.